Back to Products
S307 Breathing Apparatus Filling Station Monitor

S307 Breathing Apparatus Filling Station Monitor

The S307 Filling Station Monitor is used to monitor and control breathing apparatus filling stations’ pressure, humidity, and CO level.

  • Versatile: accepts digital and analog inputs
  • Compact: fits wherever you need it to
  • Automated: built-in alarm can be set to automatically shut off compressor

Description

S307 Breathing Apparatus Filling Station Monitor

Description

The S307 Filling Station Monitor is used to monitor and control breathing apparatus filling stations’ pressure, humidity, and CO level. Using programmed alarm settings, the display detects and indicates limits, activating relays to shut down the compressor as needed. The pressure and humidity sensor are installed into the high pressure pipe. The display unit is available in panel- or wall-mounted versions. Under regular operating conditions the optional CO sensor has a lifetime of 2 years, and sensors can be easily replaced by service personnel.

Benefits

Benefit Icon

Increased Safety

Via automated shutdown and precision alerting

Benefit Icon

Easy to Use

Display clearly reveals all necessary information

Benefit Icon

Sensors You Can Count On

Rugged IP65 casing protects from even the harshest conditions

Features

Features

  • Easy to Use: User-friendly design
  • Compact Design: Makes it easy to fit into the application
  • Signal Inputs: Digital and analog input
  • Alarm Relay: React if your humidity changes

Specs

specs

  • Dew point sensor:   Polymer
  • Temperature sensor:   NTC
  • Pressure sensor:   N/A
  • Accuracy:
    • Dew point:   ±2°C Td
    • Temperature:   0.3°C
  • Operating Pressure:   0.3 … 1.5 Mpa
  • Operating Temperature (Medium):  -30 … +70°C
  • Measured gasses (Medium):  Non-corrosive gasses
  • Response Time t90 (@ 4 l/min):
    • -50°C Td -> -20°C Td = 20 sec
    • 0°C Td -> -40°C Td = 120 sec
  • Ambient Temperature:   -10 … +40°C
  • Ambient Humidity:   0 … 100% rH
  • Supply Voltage (model depending):  100 … 240 VAC 24 VDC
  • Current consumption (model depending):  40 mA @ 220 VAC 120 mA @ 24 VDC
  • Output signals:   4 … 20 mA 3-Wire
  • Electrical connection:   Screw terminals
  • Process connection:   6 mm quick connector
  • Casing material:   ABS, Aluminum alloy
  • Classification:   IP65
  • EMC:  IEC 61326-1
  • Sensor protection:   Sinter filter
  • Transport Temperature:   -30 … +70°C
  • Storage Temperature:   0 … +40°C
  • Weight:   520 g

Documents

S307-Catalog

Catalog Cover S307-Catalog (1 MB)